Acquiring vibration data is only part of the challenge of vibration measurement; the other part is the analysis of the data acquired. It’s important to understand the types of waveforms associated with vibration analysis, the important differences between them and when it is appropriate to use each type of vibration analysis tool. Here’s a quick overview of some of the basics.
This blog will discuss and compare several different ways to analyze your vibration data. And for a deeper dive, read our handbook on Vibration Measurements.
Vibration analysis starts with a time-varying, real-world signal from a transducer or sensor. Analyzing vibration data in the time domain (amplitude plotted against time) is limited to a few parameters in quantifying the strength of a vibration profile: amplitude, peak-to-peak value, and RMS, which are identified in this simple sine wave.
Vibration is an oscillating motion about equilibrium so most vibration analysis looks to determine the rate of that oscillation or the frequency, which is proportional to the system’s stiffness. The number of times a complete motion cycle occurs during a period of one second is the vibration’s frequency and is measured in hertz (Hz). For simple sine waves, the vibration frequency could be determined from looking at the waveform in the time domain; however, as different frequency components and noise are added, spectrum analysis is necessary to obtain a clearer picture of the vibration frequency.
The fast Fourier transform (FFT) is an efficient algorithm used to compute a discrete Fourier transform (DFT). This Fourier transform outputs vibration amplitude as a function of frequency so that the analyzer can understand what is causing the vibration. The frequency resolution in an FFT is directly proportional to the signal length and sample rate. To improve the resolution, the time of the recording must be extended, but be careful of a changing vibration environment.
A spectrogram takes a series of FFTs and overlaps them to illustrate how the spectrum (frequency domain) changes with time. If vibration analysis is being done on a changing environment, a spectrogram can be a powerful tool to illustrate exactly how that spectrum of the vibration changes.
A power spectral density (PSD) takes the amplitude of the FFT, multiplies it by its complex conjugate and normalizes it to the frequency bin width. This allows for accurate comparison of random vibration signals that have different signal lengths. For this reason, PSDs are typically used to describe random vibration environments like those specified in military and commercial test standards.
To learn more about vibration analysis, read my blog Vibration Analysis: FFT, PSD, and Spectrogram Basics. Also check out our handbook on Vibration Measurements. Or for guidance on the most appropriate approach to vibration analysis for your application, contact us for guidance.
For more on this topic, visit our dedicated Vibration Loggers & Vibration Sensors resource page. There you’ll find more blog posts, case studies, webinars, software, and products focused on your vibration testing and analysis needs.